D41 Series MOV Block for Substation Arrester
|
Supply Ability: |
|
Related proudcts |
metal oxide varistor calculato, |
Specifications |
metal oxide varistor calculator |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
D41 Series MOV Block for Substation Arrester D41 Series MOV for Substation Arrester offers superior surge protection for 35kV heavy load applications. It is a reliable, cost-effective solution that is easy to install and maintain. The varistors offer a wide range of protection, including lightning and surge protection, for all types of substation equipment. Its advanced design ensures that it can withstand high voltages, making it an ideal choice for substations. Its co***ct size also makes it easy to install and maintain. The D41 Series MOV for Substation Arrester is the perfect choice for protecting your substation equipment and ensuring uninterrupted service.
The nouns, parameters and corresponding test methods in this parameter list conform to the standards of IEC60099-4:2014 and GB11032-2020.
The rated voltage, power frequency reference current and power frequency reference voltage are reference values.
The 2ms square wave tolerance value is based on the declared current/2ms repetitive charge transfer charge Qrs=423, if the actual test waveform 2ms current/2mS repetitive charge transfer charge Qrs is not equal to 423, it should be corrected according to the actual 2ms current waveform and Qrs value.
The charging rate of the aging test was 90%.
The number of pulses for the high current withstand value is two.
The nouns, parameters and corresponding test methods in this parameter list conform to the standards of IEC60099-4:2014 and GB11032-2020.
The rated voltage, power frequency reference current and power frequency reference voltage are reference values.
The 2ms square wave tolerance value is based on the declared current/2ms repetitive charge transfer charge Qrs=423, if the actual test waveform 2ms current/2mS repetitive charge transfer charge Qrs is not equal to 423, it should be corrected according to the actual 2ms current waveform and Qrs value.
The charging rate of the aging test was 90%.
The number of pulses for the high current withstand value is two.
|